Starlight Fitting and Lining Care Instructions |
|
|
|

INSTRUCTIONS FOR ASSEMBLING 2-CHANNEL STARLIGHT ELECTRIC SYSTEM
- Raise linings in normal way but to waist height only.
- Ensure the Master Looms (2 off per cloth) are situated along the same side of the cloth(s) and plug into next Master Looms if further roofs to be connected.
- Plug each Master Loom into a transformer using low voltage leads supplied (each
transformer will run approximately 320 bulbs).
- Connect each Transformer to the Cross Fade Controller. This controller then
should be connected to the mains 13amp power supply.
- Check operation of lighting system before pulling up linings in the normal way.
Starlight Linings fitting and care Instructions
Care
- Take care with handling - the bulbs are fragile (do not stand on roofs when installing)
- Ensure linings are kept clean and dry.
- When fitting check wiring looms are not caught on sewn on hooks.
- When removing, fold carefully with bulbs to the inside and return to bin provided.
Installation
- Always ensure black master looms are all down one side.
- Ensure all plugs are connected correctly together.
- On 2-channel roofs make sure yellow goes to yellow and blue-to-blue.
- 2 channel roofs require 2 transformers (1 per channel)
- Tie the centre of roofs to lifting poles.
- Lift roofs to just above head height.
- Fit outer edges to eaves.
- Velcro roofs together.
- Connect to mains and check electrics are functioning.
- Lift to desired height.
Wiring
- Input = 240v.
- Single transformers will run 300 bulbs safely.
- This equates to a maximum of 2 x 12m roofs or 3 x 9m roofs (single channel).
- 2 transformers will run 3 x 15m two-channel roofs.
- There is a thermal reset on each transformer. Damp or overload are common causes of tripping.
- Roof circuits run at 26v
- Lamp looms fused with 2amp slow burn fuses
Safety
- Do not remove plugs fitted to transformers.
- Each transformer is fitted with a thermal reset button.
- Damp or over load are common causes of tripping.
- Lamploom fuses will blow if there are more than six bulbs out or if there is a short circuit.
- Approx. power requirements. 9m =140w 12m =160w 15m =120w per channel
- Roof circuits run at 26v
- Lamp looms fused with 2amp slow burn fuses
- Spare fuses are available if required. (If hire roof they are located in lid of bin)
Simple Fault finding
- If transformer trips check for damp in plugs or over load of circuit.
- If lights are not working check roofs are plugged together and are connected to the mains and the mains supply is working.
- Check you have the maximum amount of roofs connected for the transformer to run.
- Single lamp loom not working
- Check lamp loom fuse, spares available if required. (If hire roof they are located in lid of bin)
- Check if the bayonet connection is loose or lamp loom holder damaged.
|
|
|
|
|
|
|
|